Post

New research · Ophthalmology
BMC ophthalmology · 14h
Case-controlBMC ophthalmology · 2026

Factors leading to high intraocular pressure in Intraocular Device-Associated Uveitis (IDAU): a retrospective nested case-control study from a tertiary uveitis cohort.

Jakkrit Juhong, Thanapong Somkijrungroj, Wijak Kongwattananon … Krit Pongpirul
Read paper
OphthalmologyCase-control

Intraocular lens malposition strongly associated with high eye pressure in device-associated uveitis

Factors leading to high intraocular pressure in Intraocular Device-Associated Uveitis (IDAU): a retrospective nested case-control study from a tertiary uveitis cohort.

Jakkrit Juhong … Krit Pongpirul
BMC ophthalmology · 2026
Background

Elevated intraocular pressure (IOP) is a major driver of visual morbidity in intraocular device-associated uveitis, but the risk factors that predispose affected patients to IOP elevation remain poorly characterised.

Purpose

We aimed to describe the clinical spectrum of intraocular device-associated uveitis and to identify independent risk factors for elevated IOP in this population, using the Chulalongkorn University Uveitis Cohort (CU 2 C) database.

Methods

This first nested case-control study within the Chulalongkorn University Uveitis Cohort (CU²C) enrolled 375 subjects followed at a tertiary uveitis clinic in Thailand over 8 years (August 2014-June 2022).

n = 375 subjects
Results

Intraocular lens malposition (lens shifted from position) sharply raises odds of high eye pressure

AOR by subgroup · 95% CI
null = 1
malposition
8.30
long eye
8.08
age
1.18
More results

We retrospectively identified 90 subjects who developed intraocular device-associated uveitis.

Three factors were significantly associated with high intraocular pressure in intraocular device-associated uveitis.

“
Conclusion · 1 of 2

In this first nested case-control study of intraocular device-associated uveitis, intraocular lens malposition, long axial length (> 25 mm), and older age were independently associated with elevated IOP.

Conclusion · 2 of 2

These findings should inform clinician awareness and post-operative monitoring strategies for high-risk intraocular device-associated uveitis patients.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving