Factors leading to high intraocular pressure in Intraocular Device-Associated Uveitis (IDAU): a retrospective nested case-control study from a tertiary uveitis cohort.

Jakkrit Juhong, Thanapong Somkijrungroj, Wijak Kongwattananon … Krit Pongpirul
Read paper
OphthalmologyCase-control

Intraocular lens malposition strongly associated with high eye pressure in device-associated uveitis

Factors leading to high intraocular pressure in Intraocular Device-Associated Uveitis (IDAU): a retrospective nested case-control study from a tertiary uveitis cohort.

Jakkrit Juhong … Krit Pongpirul
BMC ophthalmology · 2026
Background

Elevated intraocular pressure (IOP) is a major driver of visual morbidity in intraocular device-associated uveitis, but the risk factors that predispose affected patients to IOP elevation remain poorly characterised.

Purpose

We aimed to describe the clinical spectrum of intraocular device-associated uveitis and to identify independent risk factors for elevated IOP in this population, using the Chulalongkorn University Uveitis Cohort (CU 2 C) database.

Methods

This first nested case-control study within the Chulalongkorn University Uveitis Cohort (CU²C) enrolled 375 subjects followed at a tertiary uveitis clinic in Thailand over 8 years (August 2014-June 2022).

n = 375 subjects
Results

Intraocular lens malposition (lens shifted from position) sharply raises odds of high eye pressure

AOR by subgroup · 95% CI
null = 1
malposition
8.30
long eye
8.08
age
1.18
More results

We retrospectively identified 90 subjects who developed intraocular device-associated uveitis.

Three factors were significantly associated with high intraocular pressure in intraocular device-associated uveitis.

“
Conclusion · 1 of 2

In this first nested case-control study of intraocular device-associated uveitis, intraocular lens malposition, long axial length (> 25 mm), and older age were independently associated with elevated IOP.

Conclusion · 2 of 2

These findings should inform clinician awareness and post-operative monitoring strategies for high-risk intraocular device-associated uveitis patients.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Cross-sectional
44.1%
had too much homocysteine in the blood, a far larger share than in dry AMD or healthy eyes
Cohort Study
92.3%
most laser-treated eyes had a favorable eye-structure outcome
Cohort Study
56%
lost three or more lines on the eye-chart vision test
Cohort Study
50%
older patients were more likely to lose three or more lines of vision
Study
81%
trials where mask air leaks were detected blowing toward the eyes
Cohort Study
13.5%
Central retinal artery peak blood-flow speed was 13.5% lower in diabetic patients.
Study
379 +/- 156 microm
lower thickness in the central retina, checked with an eye scan
Case Report
9 of 10 eyes
eyes had better measured vision after treatment