Post

New research · Ophthalmology
Annals of nuclear medicine · 15h
Cohort studyAnnals of nuclear medicine · 2025

Diagnostic value of 18 F-FDG PET/CT in the follow-up of conjunctival melanoma.

Huan Ma, Chuangui Li, Qian Zhang … Daxi Xue
Read paper
OphthalmologyCohort study

PET/CT detects metastatic conjunctival melanoma with 94% overall accuracy in follow-up.

Diagnostic value of 18 F-FDG PET/CT in the follow-up of conjunctival melanoma.

Huan Ma … Daxi Xue
Annals of nuclear medicine · 2025
Purpose

To evaluate the diagnostic performance of 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) in detecting metastatic conjunctival melanoma (conjunctival melanoma).

Methods

This retrospective study enrolled 67 patients with histopathologically confirmed conjunctival melanoma who underwent 18 F-FDG PET/CT for follow-up or suspected recurrence.

n = 67 patients
Results

how often the scan correctly told spread vs. no spread - higher is better

81.3%
Sensitivity
98%
Specificity
More results

The median interval from surgery to metastasis was 20.3 months (range 1-100 months), with 56.3% (9/16) occurring within the first postoperative year.

Lymph node metastases in conjunctival melanoma predominately occurred in ipsilateral regional nodes (90.1%), with rare bilateral involvement (9.1%).

More results

Standardized uptake value of metastatic lymph nodes, lung metastases, and liver metastases showed positive correlations with lesion size (p < 0.05 for all).

Among metastatic lymph nodes, 53.2% had a short-axis diameter < 10 mm, and 59.1% of bone metastases exhibited no abnormal CT density.

“
Conclusion

18 F-FDG PET/CT provides high diagnostic accuracy in detecting systemic metastases of conjunctival melanoma during follow-up assessments, particularly for small lymph nodes, early bone metastases, and uncommon sites.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving