StudyRadiological physics and technology · 2026

Dosimetric comparison of seed-less and multi-seed 125 I eye plaque: a Monte Carlo study.

Subhalaxmi Mishra, T Palani Selvam, Munir S Pathan, B K Sapra
Read paper
OphthalmologyStudy

Seed-less eye plaques retain more radiation dose at the tumor's deep edge than multi-seed plaques.

Dosimetric comparison of seed-less and multi-seed 125 I eye plaque: a Monte Carlo study.

Subhalaxmi Mishra … B K Sapra
Radiological physics and technology · 2026
Purpose

This study presents a comprehensive dosimetric comparison between Collaborative Ocular Melanoma Study (Collaborative Ocular Melanoma Study) eye plaque containing 125 I seeds and a novel seed-less design plaque of similar shape and radioactive strength using high-precision Monte Carlo Technique.

Results

seed-less design keeps more dose reaching the tumor's deep edge

23.7%
Seed-less
16.4%
Multi-seed
More results

Monte Carlo-based dose distributions such as central axis depth dose, lateral off-axis dose profiles and 2-dimensional isodose distributions for three different plaque diameters 10, 14 and 20 mm are calculated and compared with the dose distributions of analogous seed-less plaques.

More results

Seed-less plaque of 10 mm diameter produces comparable dose distribution with the corresponding multi-seed plaque design.

Seed-less plaques of 14 mm and 20 mm diameter deliver dose rates approximately twice as high as the corresponding multi-seed plaques.

“
Conclusion

By providing superior tumour dose uniformity and improved organs at risk protection, seed-less plaques represent a promising, dosimetrically superior alternative for management of large intraocular masses.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving