Dosimetric comparison of seed-less and multi-seed 125 I eye plaque: a Monte Carlo study.

Subhalaxmi Mishra, T Palani Selvam, Munir S Pathan, B K Sapra
Read paper
OphthalmologyStudy

Seed-less eye plaques retain more radiation dose at the tumor's deep edge than multi-seed plaques.

Dosimetric comparison of seed-less and multi-seed 125 I eye plaque: a Monte Carlo study.

Subhalaxmi Mishra … B K Sapra
Radiological physics and technology · 2026
Purpose

This study presents a comprehensive dosimetric comparison between Collaborative Ocular Melanoma Study (Collaborative Ocular Melanoma Study) eye plaque containing 125 I seeds and a novel seed-less design plaque of similar shape and radioactive strength using high-precision Monte Carlo Technique.

Results

seed-less design keeps more dose reaching the tumor's deep edge

23.7%
Seed-less
16.4%
Multi-seed
More results

Monte Carlo-based dose distributions such as central axis depth dose, lateral off-axis dose profiles and 2-dimensional isodose distributions for three different plaque diameters 10, 14 and 20 mm are calculated and compared with the dose distributions of analogous seed-less plaques.

More results

Seed-less plaque of 10 mm diameter produces comparable dose distribution with the corresponding multi-seed plaque design.

Seed-less plaques of 14 mm and 20 mm diameter deliver dose rates approximately twice as high as the corresponding multi-seed plaques.

“
Conclusion

By providing superior tumour dose uniformity and improved organs at risk protection, seed-less plaques represent a promising, dosimetrically superior alternative for management of large intraocular masses.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Cross-sectional
44.1%
had too much homocysteine in the blood, a far larger share than in dry AMD or healthy eyes
Cohort Study
92.3%
most laser-treated eyes had a favorable eye-structure outcome
Cohort Study
56%
lost three or more lines on the eye-chart vision test
Cohort Study
50%
older patients were more likely to lose three or more lines of vision
Study
81%
trials where mask air leaks were detected blowing toward the eyes
Cohort Study
13.5%
Central retinal artery peak blood-flow speed was 13.5% lower in diabetic patients.
Study
379 +/- 156 microm
lower thickness in the central retina, checked with an eye scan
Case Report
9 of 10 eyes
eyes had better measured vision after treatment