Post

New research · Ophthalmology
American journal of ophthalmology · 14h
AI / informaticsAmerican journal of ophthalmology · 2026

Deep Learning-Based Diagnostic Model for Ocular Surface Neoplastic Diseases.

Rie Sakata, Taiyo Shijo, Yuta Ueno … Takefumi Yamaguchi
Read paper
OphthalmologyAI / informatics

Deep learning model diagnosed ocular surface tumors more accurately than ophthalmologists and residents.

Deep Learning-Based Diagnostic Model for Ocular Surface Neoplastic Diseases.

Rie Sakata … Takefumi Yamaguchi
American journal of ophthalmology · 2026
Purpose

To develop a deep learning (deep learning) model for diagnosing ocular surface tumors and evaluating its diagnostic performance.

Methods

A total of 1491 ocular surface images representing 7 diseases-nevus (28 eyes), limbal dermoid (144), MALT lymphoma (20), ocular surface squamous neoplasia (OSSN; 138), melanoma (14), pinguecula (29), and pterygium (1,118)-were captured using slit-lamp microscopy.

n = 28 eyes
Results

the model correctly identified the tumor type almost every time

96%
DL model
95%
Corneal specialists
82.6%
Board-certified ophtha
81.9%
Residents
More results

Disease-specific PPVs were: nevus 75.0%, limbal dermoid 93.5%, MALT lymphoma 57.9%, OSSN 87.0%, melanoma 38.5%, pinguecula 82.1%, and pterygium 96.7%.

More results

The area under the curve (AUC) was: nevus 0.897 (95% confidence interval [CI], 0.810-0.983), limbal dermoid 0.998 (95% CI, 0.996-1.000), MALT lymphoma 0.894 (95% CI, 0.794-0.993), OSSN 0.954 (95% CI, 0.933-0.975), melanoma 0.966 (95% CI, 0.919-1.000), pinguecula 0.954 (95% CI, 0.912-0.995), and pterygium 0.984 (95% CI, 0.976-0.992).

“
Conclusion · 1 of 2

The deep learning model demonstrated high diagnostic accuracy for common ocular surface tumors such as pterygium and limbal dermoid, while diagnostic performance for rare malignancies, including melanoma and MALT lymphoma, remains limited and requires further refinement.

Conclusion · 2 of 2

SYNOPSIS: We developed a deep learning model that demonstrated promising performance in identifying ocular surface neoplastic diseases, suggesting its potential as a supportive diagnostic tool in ophthalmic practice.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving