Transscleral photodynamic therapy with a chlorin e6: An experimental study of exposure parameters and therapeutic window.

Ernest V Boiko, Elena V Samkovich, Irina E Panova … Alexandra E Kim
Read paper
OphthalmologyAnimal / preclinical

In rabbits, temperature rise up to 4.5°C gave selective choroidal damage without retinal or scleral injury.

Transscleral photodynamic therapy with a chlorin e6: An experimental study of exposure parameters and therapeutic window.

Ernest V Boiko … Alexandra E Kim
PloS one · 2026
Purpose

To define optimal exposure parameters and the therapeutic window for transscleral photodynamic therapy (transscleral photodynamic therapy) with chlorin e6 by evaluating clinical, histological, and thermal effects of subthreshold, therapeutic, and suprathreshold settings in rabbit eyes.

Methods

The study was conducted on 21 healthy rabbits.

n = 21 healthy rabbits
ΔT ≤ 4.5°C
Results
ΔT ≤ 4.5°C
Keeping tissue heating under 4.5°C spared the retina and sclera during treatment.
n = 21 healthy rabbits
More results

Fundus examination on day 14 revealed distinct treatment zones correlating with laser settings.

Suprathreshold settings (≥0.3 W for 5 mm; ≥ 0.6 W for 10 mm) induced retinal necrosis (up to 50%) and scleral coagulation (ΔT ≥ 8°C) with power densities exceeding 0.866 W/cm² (5 mm) and 0.764 W/cm² (10 mm).

“
Conclusion · 1 of 2

Transscleral photodynamic therapy with chlorin e6 enables selective targeting of intraocular pathological tissues while preserving scleral and retinal integrity.

Conclusion · 2 of 2

Defining the therapeutic window and using real-time thermal monitoring enhances treatment safety. These findings lay a foundation for clinical protocols for uveal melanoma and other intraocular tumors.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Cross-sectional
44.1%
had too much homocysteine in the blood, a far larger share than in dry AMD or healthy eyes
Cohort Study
92.3%
most laser-treated eyes had a favorable eye-structure outcome
Cohort Study
56%
lost three or more lines on the eye-chart vision test
Cohort Study
50%
older patients were more likely to lose three or more lines of vision
Study
81%
trials where mask air leaks were detected blowing toward the eyes
Cohort Study
13.5%
Central retinal artery peak blood-flow speed was 13.5% lower in diabetic patients.
Study
379 +/- 156 microm
lower thickness in the central retina, checked with an eye scan
Case Report
9 of 10 eyes
eyes had better measured vision after treatment