Post

New research · Ophthalmology
PeerJ · 2d
Cohort studyPeerJ · 2026

Psychometric evaluation of the Chinese revised Sensory Integration and Praxis Tests in children with amblyopia.

Meng Ru, Lu Pan, Yuxing Huang … Xin Xiao
Read paper
OphthalmologyCohort study

Chinese SIPT-R test shows excellent internal reliability for amblyopic children

Psychometric evaluation of the Chinese revised Sensory Integration and Praxis Tests in children with amblyopia.

Meng Ru … Xin Xiao
PeerJ · 2026
Background

Children with amblyopia commonly present with sensory integration difficulties, however, there is a paucity of validated tools to assess these issues in this clinical population.

Purpose

This study aimed to evaluate the psychometric properties of the Chinese Revised version of the Sensory Integration and Praxis Tests (SIPT-R) for use in children with amblyopia.

Methods

Included 629 children aged 4-9 years diagnosed with amblyopia; subtypes included bilateral ametropic (55.7%), anisometropic (38.8%), and strabismic amblyopia (5.6%).

n = 629 children
0.968 - 0.969
Results
0.968 - 0.969
children answer sensory questions consistently across repeat testing
n = 629 children
More results

All split-half coefficients exceeded 0.80.

More results

Confirmatory factor analysis indicated an acceptable model fit for both age groups: for aged 4-5 years, χ 2 / df = 2.712, root mean square error of approximation (root mean square error of approximation) = 0.079, comparative fit index (comparative fit index) = 0.832, incremental fit index (incremental fit index) = 0.833; for aged 6-9 years, χ 2 / df = 2.951, root mean square error of approximation = 0.074, comparative fit index = 0.804, incremental fit index = 0.805.

“
Conclusion · 1 of 2

The Chinese revised SIPT-R demonstrates strong reliability and acceptable validity for screening sensory integration function in children with amblyopia.

Conclusion · 2 of 2

Further research should focus on refining specific subscales and evaluating additional psychometric properties, such as test-retest reliability and criterion validity.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving