Post

New research · Ophthalmology
Contact lens & anterior eye : the journal of the British Contact Lens Association · 2d
StudyContact lens & anterior eye : the journal of the British Contact Lens Association · 2026

Effect of a head strap on the function of an eyelid warming compress.

Mou Saha, Ana Mustahsin, James S Wolffsohn, Sònia Travé-Huarte
Read paper
OphthalmologyStudy

Eyelid warming compress heated eyelids more when the head strap was left off

Effect of a head strap on the function of an eyelid warming compress.

Mou Saha … Sònia Travé-Huarte
Contact lens & anterior eye : the journal of the British Contact Lens Association · 2026
Purpose

This study investigated whether the presence of a strap clinically influences the performance of such eye masks.

Methods

The surface temperature decline of a Blepha EyeBag® eye mask (Théa Pharmaceuticals Limited,UK) placed on the facial area of a composite manikin head was measured with a thermographer following heating in a domestic microwave for 30, 45 and 60 s at a 800mw settings.

1.9
Results
1.9
± 2.2 °C
eyelid surface got warmer when the head strap was left off
More results

The upper and lower eyelids heated to a similar temperature (on average 31.1 ± 5.1 °C vs 31.2 ± 5.4 °C, respectively; F = 0.064, p = 0.805), with temperate systematically increasing with Blepha EyeBag® heating time (F = 74.027, p < 0.001).

More results

The temperature dropped with time following heating (F = 56.483, p < 0.001) in a similar manner with and without the strap in place F = 1.949, p = 0.221).

“
Conclusion

The temperature transference to the eyelid surfaces was higher without the strap (on average by 1.9 ± 2.2 °C) possibly because the mask could conform to the contours of the face better when it wasn't pulled tight.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving