Post

New research · Ophthalmology
Diagnostics (Basel, Switzerland) · 2d
Randomized trialDiagnostics (Basel, Switzerland) · 2026

Feasibility of Intraoperative SS-OCT for Assessing Capsular-Bag Dynamics During Cataract Surgery: Pilot Randomized Intra-Individual Comparison of Adaptive Versus Gravity-Based Fluidics.

Stefan Georgiev, Stefan Palkovits, Andreea Dana-Fisus … Oliver Findl
Read paper
OphthalmologyRandomized trial

Intraoperative eye-imaging scans during cataract surgery were only partly successful.

Feasibility of Intraoperative SS-OCT for Assessing Capsular-Bag Dynamics During Cataract Surgery: Pilot Randomized Intra-Individual Comparison of Adaptive Versus Gravity-Based Fluidics.

Stefan Georgiev … Oliver Findl
Diagnostics (Basel, Switzerland) · 2026
Background

This exploratory, randomized, patient-masked, intra-individual pilot study evaluated the feasibility of intraoperative swept-source optical coherence tomography (swept-source optical coherence tomography) for quantifying capsular-bag dynamics during cataract surgery and explored potential differences between an adaptive fluidics system (adaptive fluidics system) and a gravity-based fluidics system (GFS).

Methods

Twenty-seven myopic cataract patients (54 eyes) underwent bilateral phacoemulsification, with one eye randomly assigned to adaptive fluidics system and the fellow eye to GFS using the same phacoemulsification platform (Stellaris/Stellaris Elite, Bausch & Lomb, Rochester, NY, USA).

n = 54 eyes
60.5%
Results
60.5%
of scans yielded usable eye-capsule images, showing feasibility limits
n = 54 eyes
More results

However, this difference was not statistically significant after adjustment for multiple comparisons.

No significant inter-system differences were found at other timepoints, and overall discomfort scores were similar ( p = 0.70).

“
Conclusion · 1 of 3

Intraoperative swept-source optical coherence tomography enabled real-time visualization and partial quantitative assessment of capsular-bag dynamics during cataract surgery.

Conclusion · 2 of 3

The observed difference at the initiation of phacoemulsification may suggest reduced anterior-capsule deepening with adaptive fluidics, but this comparison was not statistically significant after multiplicity adjustment.

Conclusion · 3 of 3

The 39.5% measurement failure rate underscores the need for technical refinement before routine clinical implementation.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving