Post

New research · Ophthalmology
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 4d
StudyPhysica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026

Comparison of model-based and delineation-based target volume definition for ocular proton therapy.

Lisa Klaassen, Coen R N Rasch, Jan-Willem M Beenakker
Read paper
OphthalmologyStudy

Model-based tumor contouring overestimates delineated uveal melanoma volume to ensure coverage.

Comparison of model-based and delineation-based target volume definition for ocular proton therapy.

Lisa Klaassen … Jan-Willem M Beenakker
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
Background

In recent years, eye-specific, high-resolution MRI protocols have become available for ocular tumours, enabling 3D tumour delineation.

Methods

Tumours were delineated for 70 uveal melanoma patients.

n = 70 patients
Results

at that coverage level, contouring added extra tumor volume beyond the true tumor

16.4%
Irregularly shaped
36.6%
Dome-shaped
More results

For 69/70 patients, an acceptable tumour model could be generated, out of whom 12/69 needed an expansion of the tumour base or added tumour thickness to produce at least one acceptable model.

Irregularly shaped tumours showed larger overestimations than dome-shaped tumours (16.4% vs 36.6%, p < 0.001).

“
Conclusion

Tumour models as used in ocular proton therapy treatment planning systems can achieve acceptable tumour coverage. However, to achieve this coverage, the tumour models overestimated the delineated tumour volume.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving