Post

New research · Ophthalmology
American journal of ophthalmology · 4d
StudyAmerican journal of ophthalmology · 2026

Performance of the ISOLD Score (Interleukin Score for IntraOcular Lymphoma Diagnosis) in the Diagnosis of Vitreoretinal Lymphoma in Clinical Practice.

Martin Chevalier, Elise Sourdeau, Magali Le Garff-Tavernier … Bahram Bodaghi
Read paper
OphthalmologyStudy

ISOLD score accurately diagnosed vitreoretinal lymphoma from aqueous humor samples.

Performance of the ISOLD Score (Interleukin Score for IntraOcular Lymphoma Diagnosis) in the Diagnosis of Vitreoretinal Lymphoma in Clinical Practice.

Martin Chevalier … Bahram Bodaghi
American journal of ophthalmology · 2026
Purpose

To evaluate the real-world diagnostic performance of the ISOLD score-a probabilistic formula based on absolute intraocular IL-10 and IL-6 levels-and to compare it with absolute cytokine thresholds and the IL-10/IL-6 ratio for vitreoretinal lymphoma (vitreoretinal lymphoma) diagnosis.

Methods

One hundred sixty-six patients who underwent intraocular sampling for IL-6 and IL-10 measurement at a tertiary vitreoretinal lymphoma referral center between January 2017 and June 2019, yielding 183 samples (156 aqueous humor from anterior chamber paracentesis and 27 vitreous).

n = 183 samples
Results

test correctly told apart lymphoma from non-lymphoma eye-fluid samples nearly every time

86.8%
Sensitivity
98.6%
Specificity
More results

At a threshold of 0, the ISOLD score yielded overall sensitivity of 86.8%, specificity of 98.6%, PPV of 94.3%, and NPV of 96.6% across all 183 samples.

More results

The IL-10/IL-6 ratio at a threshold of 0.6 in aqueous humor (n=150) demonstrated sensitivity 77.8%, specificity 93.9%, PPV 63.6% and NPV 96.9%; at a threshold of 1 in vitreous (n=27), sensitivity, specificity, PPV, and NPV were 80%, 100%, 100%, and 63.6%, respectively.

“
Conclusion · 1 of 3

The ISOLD score is a reliable tool for vitreoretinal lymphoma diagnosis in routine clinical practice, with performance validated primarily on aqueous humor samples obtained by anterior chamber paracentesis.

Conclusion · 2 of 3

It outperforms the IL-10/IL-6 ratio alone by providing a continuous probabilistic estimate. False-negative results may occur in immunosuppressed patients or those receiving corticosteroids or chemotherapy.

Conclusion · 3 of 3

A larger vitreous sample would be required to draw definitive conclusions regarding ISOLD performance on this specimen type.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Cross-sectional
44.1%
had too much homocysteine in the blood, a far larger share than in dry AMD or healthy eyes
Cohort Study
92.3%
most laser-treated eyes had a favorable eye-structure outcome
Cohort Study
56%
lost three or more lines on the eye-chart vision test
Cohort Study
50%
older patients were more likely to lose three or more lines of vision
Study
81%
trials where mask air leaks were detected blowing toward the eyes
Cohort Study
13.5%
Central retinal artery peak blood-flow speed was 13.5% lower in diabetic patients.
Study
379 +/- 156 microm
lower thickness in the central retina, checked with an eye scan
Case Report
9 of 10 eyes
eyes had better measured vision after treatment