Post

New research · Ophthalmology
Ophthalmology science · 4d
Cohort studyOphthalmology science · 2026

Development and Clinical Validation of a Digital Eye-Tracking-Based Cover Test for Ocular Misalignment.

Eduardo Esteban-Ibañez, David Solanas, Marta Lacort-Beltrán … Victoria Pueyo
Read paper
OphthalmologyCohort study

Digital eye-tracking cover test detects ocular misalignment with high sensitivity and specificity.

Development and Clinical Validation of a Digital Eye-Tracking-Based Cover Test for Ocular Misalignment.

Eduardo Esteban-Ibañez … Victoria Pueyo
Ophthalmology science · 2026
Purpose

To develop and clinically validate the DIVE Cover Test (DIVE Cover Test), a portable eye-tracking-based digital implementation of the cover test, and to assess its diagnostic accuracy, agreement with the clinical reference standard (classic cover test [CCT]), and repeatability across cover-uncover test (cover-uncover test) and alternate cover test (alternate cover test) phases and across horizontal and vertical axes.

Methods

Sixty-eight participants aged 3 to 74 years, including healthy controls and patients referred for strabismus evaluation.

85%
Results
85%
sensitivity and 98% specificity
eye-tracker correctly flagged most misaligned eyes, rarely false-alarmed on normal eyes
More results

Agreement between DIVE Cover Test and CCT was strongest for horizontal deviations, particularly during alternate cover test (mean difference -1.3 prism diopters [PD]; limits of agreement -8.0 and 5.4 PD).

More results

Intermethod ICCs were high for horizontal deviations (cover-uncover test 0.93; alternate cover test 0.96) and moderate-to-high for vertical deviations (both phases 0.81).

The DIVE Cover Test test-retest repeatability was excellent (ICC ≥0.93 across axes and phases), with narrow limits of agreement (±3.8 to ±4.6 PD).

“
Conclusion · 1 of 2

The DIVE Cover Test demonstrates high diagnostic accuracy, strong agreement with the clinical reference standard, and excellent repeatability. Phase-specific (cover-uncover test vs. alternate cover test) and axis-specific (horizontal vs.

Conclusion · 2 of 2

vertical) analyses support the DIVE Cover Test as a practical, portable, and objective tool for quantifying ocular misalignment in clinical settings.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving