Post

New research · Ophthalmology
Pharmaceutics · 4d
ReviewPharmaceutics · 2026

Punctal and Intracanalicular Drug Delivery Systems for Ophthalmic Use: A Narrative Review of Technologies, Clinical Outcomes, and Critical Quality Attributes.

Elena O Bakhrushina, Kseniia S Leonova, Nikita O Belyavsky … Vasily D Yartsev
Read paper
OphthalmologyReview

Drug-free punctal plugs are often expelled early from the tear duct opening.

Punctal and Intracanalicular Drug Delivery Systems for Ophthalmic Use: A Narrative Review of Technologies, Clinical Outcomes, and Critical Quality Attributes.

Elena O Bakhrushina … Vasily D Yartsev
Pharmaceutics · 2026
Background

Conventional ophthalmic eye drops have low bioavailability (<5%) and poor patient adherence, driving the development of sustained-release ophthalmic drug delivery systems.

Purpose

To summarize and critically appraise punctal and intracanalicular drug delivery systems, occlusive devices, and in situ-forming hydrogels with respect to composition, release mechanisms, clinical efficacy, safety, and critical quality attributes (critical quality attributes).

Methods

A narrative literature review was conducted using PubMed, Scopus, Web of Science, Google Scholar, ClinicalTrials.gov, and patent/regulatory sources, including FDA materials and Google Patents, covering 2001-2026.

57.4%
Results
57.4%
over half of drug-free plugs fell out too soon from the eye's tear duct
More results

Drug delivery systems provide release from 7 days (PEGDA hydrogels) to 3 months (Eximore, Ocular Therapeutix™).

In situ systems eliminate size-fitting requirements but face challenges related to gelation control and biodegradation.

“
Conclusion · 1 of 2

We propose the following candidate critical quality attributes: retention (>80% over 4 weeks), swelling degree (30-60%), controlled burst release (<40% within 24 h), and mechanical compatibility.

Conclusion · 2 of 2

The proposed QTPP matrices for punctal, intracanalicular, and in situ systems may guide the development of ophthalmic drug delivery platforms.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving