Post

New research · Surgery
Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 4d
Cohort studyKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026

Equivalent accuracy of image-based and imageless robotic platforms in achieving planned femoral rotation in primary total knee arthroplasty: A CT-based study.

Fabio Mancino, Ignacio Fernandez, David A Parker, Brett A Fritsch
Read paper
SurgeryCohort study

Image-based and imageless robotic platforms show equivalent accuracy in total knee arthroplasty.

Equivalent accuracy of image-based and imageless robotic platforms in achieving planned femoral rotation in primary total knee arthroplasty: A CT-based study.

Fabio Mancino … Brett A Fritsch
Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
Background

Robotic-assisted total knee arthroplasty (total knee arthroplasty) is increasingly adopted worldwide, yet comparative data on the rotational accuracy of image-based and imageless platforms remain limited.

Purpose

The aim of this study was to compare the accuracy of image-based and imageless robotic platforms in achieving planned femoral rotation in primary total knee arthroplasty.

Methods

This single-surgeon retrospective cohort study included patients undergoing image-based and imageless robotic-assisted total knee arthroplasty for primary osteoarthritis.

n = 79, image
Results

this range confirms both robotic methods are equally accurate in thigh bone rotation

imageless
1.3°
image-based
1.2°
More results

The mean rotational error was 1.3 ± 1.0° for imageless and 1.2 ± 1.2° for image-based total knee arthroplasty (p = 0.346; effect size -0.09).

Analysis of covariance demonstrated a small adjusted difference of 0.51° (p = 0.045), with minimal explained variance (adjusted R 2 = 0.01).

More results

Intra-observer reliability was excellent (intraclass correlation coefficient [ICC] 0.91), while inter-observer reliability was good (ICC 0.82).

No differences were observed in patient-reported outcomes, except lower pain scores in the image-based group at 12 months.

“
Conclusion · 1 of 2

Image-based and imageless robotic platforms demonstrated equivalent accuracy in achieving planned femoral rotation in primary total knee arthroplasty. Any observed differences were not clinically meaningful.

Conclusion · 2 of 2

LEVEL OF EVIDENCE: Level III, retrospective comparative cohort study.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Study
3.2%
had surgery-entry retinal tears during the procedure
Cohort Study
0.034 %
lower rate of serious eye infection after cataract surgery with cefuroxime
Cohort Study
100%
vision improved after surgery in every case where the retina had detached from the macula
Cohort Study
48.9%
eyes developed a scar-like membrane on the retina after repair
Cohort Study
26%
developed swelling in the eye’s central retina after the combined surgery
Randomized Trial
logMAR 0.15
worse best-corrected vision in patients with visual distortion
Cohort Study
Approximately 80%
avoided the need for surgery after the injection treatment
Study
2.1 kPa
This is the highest stress on the fovea due to membrane pulling