Post

Rita Ehrlich
The British journal of ophthalmology
12y
Cohort studyThe British journal of ophthalmology · 2014

Intracameral recombinant tissue plasminogen activator (r-tPA) for refractory toxic anterior segment syndrome.

Assaf Dotan, Igor Kaiserman, Israel Kremer … Irit Bahar
Read paper
OphthalmologyCohort study

Recombinant tissue plasminogen activator was associated with fibrin reaction resolution after cataract surgery.

Intracameral recombinant tissue plasminogen activator (r-tPA) for refractory toxic anterior segment syndrome.

Assaf Dotan … Irit Bahar
The British journal of ophthalmology · 2014
Purpose

To investigate the therapeutic effect of recombinant tissue plasminogen activator (r-tPA) in patients with refractory toxic anterior chamber segment syndrome after cataract surgery with posterior chamber intraocular lens implantation.

Methods

This prospective cohort study was performed from May 2010 to November 2011 at a tertiary university-based medical centre.

n = 40 eyes
95%
Results
95%
had complete clearing of the fibrin buildup in the eye after one month
n = 40 eyes
More results

At 1 day after treatment, complete clearance of the fibrin reaction was observed in 32 patients (80%) and partial clearance in 8 (20%).

Mean visual acuity improved from 0.61±0.38 logMAR before treatment to 0.45±0.37 logMAR 1 month later (p=0.06).

More results

There were no statistically significant differences in improvement in visual acuity and fibrinolysis rate by time of r-tPA injection after surgery (10-15 days, n=16 vs 16-49 days, n=24).

There were no cases of increased intraocular pressure or endophthalmitis following the procedure.

“
Conclusion

Intracameral injection of 25 µg r-tPA is safe and effective for the treatment of refractory fibrin reaction after cataract surgery.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Cross-sectional
44.1%
had too much homocysteine in the blood, a far larger share than in dry AMD or healthy eyes
Cohort Study
92.3%
most laser-treated eyes had a favorable eye-structure outcome
Cohort Study
56%
lost three or more lines on the eye-chart vision test
Cohort Study
50%
older patients were more likely to lose three or more lines of vision
Study
81%
trials where mask air leaks were detected blowing toward the eyes
Cohort Study
13.5%
Central retinal artery peak blood-flow speed was 13.5% lower in diabetic patients.
Study
379 +/- 156 microm
lower thickness in the central retina, checked with an eye scan
Case Report
9 of 10 eyes
eyes had better measured vision after treatment