Post

Rita Ehrlich
Retina (Philadelphia, Pa.)
18y
Cohort studyRetina (Philadelphia, Pa.) · 2008

Diode laser treatment of retinopathy of prematurity: anatomical and refractive outcomes.

Ruth Axer-Siegel, Idit Maharshak, Moshe Snir … Dov Weinberger
Read paper
OphthalmologyCohort study

Laser-treated eyes had favorable anatomical outcomes in most cases.

Diode laser treatment of retinopathy of prematurity: anatomical and refractive outcomes.

Ruth Axer-Siegel … Dov Weinberger
Retina (Philadelphia, Pa.) · 2008
Purpose

To examine the anatomical and refractive outcomes of infrared diode laser photocoagulation (diode laser photocoagulation) for the treatment of threshold retinopathy of prematurity (retinopathy of prematurity).

Methods

The charts of all consecutive premature neonates with retinopathy of prematurity treated by diode laser photocoagulation at our tertiary center from December 1, 1996, to December 31, 2004, were reviewed.

n = 194 eyes
Results
92.3%
most laser-treated eyes had a favorable eye-structure outcome
n = 194 eyes
More results

The group included 100 neonates (194 eyes) with a mean birth weight +/- SD of 833.9 +/- 250.3 g and a mean gestational age +/- SD of 26 +/- 1.9 weeks.

Each eye received a mean +/- SD of 1,740 +/- 990 laser applications, and 21% of eyes received an additional 1 to 2 rows posterior to the ridge.

More results

Neonates treated after December 2003 (cutoff date of the Early Treatment of Retinopathy of Prematurity study) underwent a significantly greater number of laser applications (mean +/- SD, 2,286 +/- 1,087) than did neonates treated earlier.

Refractive data were available for 134 eyes: 55.2% had myopia of -5 diopters (31.3%) or greater (23.9%).

“
Conclusion

Diode laser photocoagulation is a safe and effective treatment for retinopathy of prematurity. Neonates of lower gestational age and birth weight require earlier and more aggressive laser treatment and may have a higher refractive error.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving