Sonorheometry Quantra QPlus Characteristics in Adult Cardiac Surgical Patients: An Observational Cohort Study.

Ziyad O Knio, Charbel A Marche, Jenna Khan … Michael A Mazzeffi
Read paper
SurgeryCohort study

PCS accurately detects low platelet counts during cardiopulmonary bypass.

Sonorheometry Quantra QPlus Characteristics in Adult Cardiac Surgical Patients: An Observational Cohort Study.

Ziyad O Knio et al. · Anesthesia and analgesia · 2026
Background

Validation of the Quantra QPlus sonorheometry cartridge (Hemosonics Corporation) in cardiac surgical patients is limited.

Methods

We performed a retrospective observational study of 511 cardiac surgical patients at a single academic medical center during the first year of routine sonorheometry application during and after cardiac surgery (2024-2025).

n = 511 cardiac surgical patients
0.98
Results
PCS showed very high accuracy detecting low platelet counts during cardiopulmonary bypass
n = 511 cardiac surgical patients
More results

A CTH value of 153 seconds discriminated elevated international normalized ratio (INR) values post-CPB, with an area under the curve (AUC) from 0.78 to 0.84 depending on the INR cutoff.

An FCS of 1.5 to 2.3 hPa discriminated hypofibrinogenemia post-CPB with an AUC from 0.88 to 0.97 depending on the fibrinogen cutoff.

More results

A PCS of 6.9 to 12.2 hPa detected thrombocytopenia post-CPB with an AUC from 0.90 to 0.97, depending on the platelet cutoff.

Platelet count was observed to be higher for a given PCS during CPB (β, 1.51) and in hypofibrinogenemic states (β, 3.13 and 4.04 for FCS 1.6-2.3 hPa and ≤1.5 hPa, respectively).

“
Conclusion · 1 of 2

CTH, PCS, and FCS demonstrated high discriminative accuracy for abnormalities in corresponding laboratory assays.

Conclusion · 2 of 2

CPB and hypofibrinogenemia modified the relationship between PCS and platelet count, with a higher platelet count observed for a given PCS during CPB and when fibrinogen was low.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Review
107 publications
volume of research papers identified on robot-assisted kidney donation surgery
Study
€406.2 million
This is the additional value angiography-guided thyroidectomy provides to the health system.
Cohort Study
30%
the non-surgical time in the operating room decreased with surgeon experience
Cohort Study
4.8% vs. 7.1%
serious problems after live-streamed surgery were similar to non-streamed surgery
Randomized Trial
83% reduction
the disparity in pre-surgery care for Hispanic/Latino patients became much smaller
AI / Informatics
C-index of 0.751
This indicates the model's high accuracy in predicting survival after surgery
Study
9.91 dB
average error in predicting hearing after ear surgery, with lower values being better
Observational
78%
the middle turbinate stayed in a stable position for most patients with the graft