Post

New research · Surgery
Anesthesia and analgesia · 1d
Cohort studyAnesthesia and analgesia · 2026

Sonorheometry Quantra QPlus Characteristics in Adult Cardiac Surgical Patients: An Observational Cohort Study.

Ziyad O Knio, Charbel A Marche, Jenna Khan … Michael A Mazzeffi
Read paper
SurgeryCohort study

PCS accurately detects low platelet counts during cardiopulmonary bypass.

Sonorheometry Quantra QPlus Characteristics in Adult Cardiac Surgical Patients: An Observational Cohort Study.

Ziyad O Knio et al. · Anesthesia and analgesia · 2026
Background

Validation of the Quantra QPlus sonorheometry cartridge (Hemosonics Corporation) in cardiac surgical patients is limited.

Methods

We performed a retrospective observational study of 511 cardiac surgical patients at a single academic medical center during the first year of routine sonorheometry application during and after cardiac surgery (2024-2025).

n = 511 cardiac surgical patients
0.98
Results
PCS showed very high accuracy detecting low platelet counts during cardiopulmonary bypass
n = 511 cardiac surgical patients
More results

A CTH value of 153 seconds discriminated elevated international normalized ratio (INR) values post-CPB, with an area under the curve (AUC) from 0.78 to 0.84 depending on the INR cutoff.

An FCS of 1.5 to 2.3 hPa discriminated hypofibrinogenemia post-CPB with an AUC from 0.88 to 0.97 depending on the fibrinogen cutoff.

More results

A PCS of 6.9 to 12.2 hPa detected thrombocytopenia post-CPB with an AUC from 0.90 to 0.97, depending on the platelet cutoff.

Platelet count was observed to be higher for a given PCS during CPB (β, 1.51) and in hypofibrinogenemic states (β, 3.13 and 4.04 for FCS 1.6-2.3 hPa and ≤1.5 hPa, respectively).

“
Conclusion · 1 of 2

CTH, PCS, and FCS demonstrated high discriminative accuracy for abnormalities in corresponding laboratory assays.

Conclusion · 2 of 2

CPB and hypofibrinogenemia modified the relationship between PCS and platelet count, with a higher platelet count observed for a given PCS during CPB and when fibrinogen was low.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Review
107 publications
volume of research papers identified on robot-assisted kidney donation surgery
Cohort Study
86.2%
patients had no urine leakage after receiving the implanted device
Cohort Study
0.58
how well patients' own frailty ratings matched trained assessors' ratings
Cohort Study
59.0%
Over two years, 59.0% of patients achieved lower eye pressure or fewer medications.
Cohort Study
4.8% vs. 7.1%
serious problems after live-streamed surgery were similar to non-streamed surgery
Study
9.91 dB
average error in predicting hearing after ear surgery, with lower values being better
Cohort Study
3:54 vs. 4:41 h
recipients had shorter surgery time with the simultaneous robotic approach
Observational
78%
the middle turbinate stayed in a stable position for most patients with the graft