Post

New research · Ophthalmology
Seminars in arthritis and rheumatism · 10h
StudySeminars in arthritis and rheumatism · 2026

Applying the consensus-based salivary glands ultrasound scoring system in lacrimal glands: results of a static image-based OMERACT reliability exercise.

Lene Terslev, Nanna Surlemont Schmidt, Viktoria Fana … on the behalf of the OMERACT Ultrasound working group
Read paper
OphthalmologyStudy

Salivary gland ultrasound scoring system shows good reliability for lacrimal glands too

Applying the consensus-based salivary glands ultrasound scoring system in lacrimal glands: results of a static image-based OMERACT reliability exercise.

Lene Terslev … on the behalf of the OMERACT Ultrasound working group
Seminars in arthritis and rheumatism · 2026
Purpose

This study tested the reliability of an ultrasound scoring system (0-3) for lacrimal glands using an OMERACT semi-quantitative ultrasound scoring system developed for salivary glands in primary Sjögrens Disease SjD).

Methods

Fourteen rheumatologists participated in a static image exercise on ultrasound images in order to evaluate the reliability of the existing salivary gland ultrasound (salivary gland ultrasound) scoring system when applied to lacrimal glands.

Results

how well different doctors' scores agreed when checking the same lacrimal gland images

kappa 0.63 (95% CI 0.61 to 0.65)
null = 00.610.65
CI excludes the null - significant
More results

The majority (11/14) had no prior experience in lacrimal gland ultrasound but 13/14 had experience in salivary gland ultrasound.

“
Conclusion · 1 of 2

The consensus-based semi-quantitative ultrasound scoring system for salivary glands showed good to excellent intra-observer and good inter-observer reliability when applied to the lacrimal glands using static images.

Conclusion · 2 of 2

The next step is to assess the reliability when scoring lacrimal glands in video-clips and in live exercises.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%