Background

Primary vitreoretinal lymphoma (primary vitreoretinal lymphoma) is a rare and aggressive intraocular malignancy that is frequently misdiagnosed because of its nonspecific early manifestations and the lack of effective screening tools.

Purpose

This study presents the noninvasive and scalable blood-based screening strategy for detection of primary vitreoretinal lymphoma, with a web application enabling timely triage and population-level risk stratification.

Methods

In the community cohort (n = 515,326), 22 individuals are flagged as high risk, 13 of whom are confirmed as having primary vitreoretinal lymphoma (positive predictive value = 59.1%).

n = 83,610 individuals
Results

of true lymphoma cases, the blood test correctly flagged 95

95%
Sensitivity
99.97%
Specificity
More results

We conduct a multicentre case-control study including 255 primary vitreoretinal lymphoma patients and 292 controls to develop a machine learning-based screening model using complete blood count data.

More results

A six-feature random forest model demonstrates high diagnostic accuracy in the discovery cohort (area under the curve [AUC] = 0.85) and validates across all cohorts (AUC = 0.80-0.83), outperforming intraocular biomarkers such as the interleukin-10/interleukin-6 ratio (AUC = 0.65-0.78).

“
Conclusion

This study presents the noninvasive and scalable blood-based screening strategy for detection of primary vitreoretinal lymphoma, with a web application enabling timely triage and population-level risk stratification.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving