Post

New research · Ophthalmology
Journal of medical radiation sciences · 16h
StudyJournal of medical radiation sciences · 2026

Comparative Evaluation of Four Stereotactic Radiosurgery Planning Approaches for Treatment of Posterior Choroidal Melanoma.

Robert Nigro, Kenton Thompson, Cathy Markham … Claire Phillips
Read paper
OphthalmologyStudy

Modulated arc techniques cut brain volume receiving 10 Gy to zero versus dynamic conformal arc therapy.

Comparative Evaluation of Four Stereotactic Radiosurgery Planning Approaches for Treatment of Posterior Choroidal Melanoma.

Robert Nigro … Claire Phillips
Journal of medical radiation sciences · 2026
Background

This was a comparative treatment planning study for posterior choroidal melanoma (choroidal melanoma) using four stereotactic approaches: Brainlab iPlan dynamic conformal arc therapy (dynamic conformal arc therapy), Brainlab Elements modulated arcs (BE), Varian Eclipse HyperArc modulated arcs (HA) and Gamma Knife ICON Leksell GammaPlan (GK).

Methods

Thirteen choroidal melanoma cases over 3 years (2015-2018) treated with dynamic conformal arc therapy prescribed 50 Gy in 5 fractions were selected.

Results

less brain tissue got a meaningful radiation dose - none did with the newer techniques

DCAT
0.93cc
GK
0cc
BE
0cc
HA
0cc
More results

Brain D near-max GK 5.52 Gy, HA 6.41 Gy, BE 7.28 Gy, dynamic conformal arc therapy 13.73 Gy (p = 0.001).

The median Gradient Index (Gradient Index) was GK 2.79, dynamic conformal arc therapy 6.39, BE 5.07, HA 6.00 (p < 0.001) with GK significantly different from each of the other approaches for PTV parameters.

“
Conclusion · 1 of 2

Modulation tools in HA and BE enabled clinically meaningful reduction in dose to brain compared with dynamic conformal arc therapy whilst maintaining dose to PTV.

Conclusion · 2 of 2

GK produced highest PTV coverage with superior gradient index, however current methods for eye immobilisation and treatment delivery only allow for single fraction treatment with GK.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving