Post

New research · Ophthalmology
The British journal of ophthalmology · 18h
StudyThe British journal of ophthalmology · 2026

Safe use of fluorinated gases in vitreoretinal surgery: learning from patient safety incidents with expert panel recommendations from the British and Eire Association of Vitreoretinal Surgeons (BEAVRS).

Fernando J Huelin, Peter Kiraly, George Moussa … on behalf ofBEAVRS board
Read paper
OphthalmologyStudy

Over a third of UK vitreoretinal surgeons recall harm from wrong gas concentration

Safe use of fluorinated gases in vitreoretinal surgery: learning from patient safety incidents with expert panel recommendations from the British and Eire Association of Vitreoretinal Surgeons (BEAVRS).

Fernando J Huelin … on behalf ofBEAVRS board
The British journal of ophthalmology · 2026
Background

Errors in intravitreal fluorinated gas selection or dilution can result in unintended expansile concentrations, causing irreversible visual loss.

Purpose

We aimed to quantify the problem using national incident reporting, published literature and a UK surgeon survey, developing expert consensus recommendations on safe storage, handling and intraocular use.

Methods

NHS England patient safety incident repositories (National Reporting and Learning System and Learn from Patient Safety Events) were searched for events related to intravitreal gas use (2010-2025), followed by thematic analysis.

n = 29 cases
Results

over a third of surgeons recall a serious complication from a wrong gas mix

Recalled significant c
38.9%
Witnessed sight-threat
16.7%
More results

National reporting identified 47 relevant incidents; 29 cases involved incorrect gas concentration due to preparation errors.

14 cases resulted in at least moderate harm, including eight with blindness or severe visual impairment; pure gas concentration (100%) administration was documented in six cases.

More results

The literature review identified 20 severe cases across 11 publications.

“
Conclusion · 1 of 2

Incorrect intraocular gas concentration is likely under-reported but can cause devastating, preventable harm.

Conclusion · 2 of 2

Standardised systems for storage, preparation, verification and postoperative review may reduce risk while supporting environmentally responsible practice.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving