Post

New research · Ophthalmology
Optometry and vision science : official publication of the American Academy of Optometry · 23h
Randomized trialOptometry and vision science : official publication of the American Academy of Optometry · 2026

Testability and test-retest reliability of SpotChecks Contrast Sensitivity Test in children with unilateral amblyopia.

Vivian M Manh, Rui Wu, Michael E Gray … Pediatric Eye Disease Investigator Group
Read paper
OphthalmologyRandomized trial

SpotChecks contrast sensitivity test needs a 4-line change to detect a real difference.

Testability and test-retest reliability of SpotChecks Contrast Sensitivity Test in children with unilateral amblyopia.

Vivian M Manh … Pediatric Eye Disease Investigator Group
Optometry and vision science : official publication of the American Academy of Optometry · 2026
Purpose

To report testability and test-retest reliability of the SpotChecks contrast sensitivity (contrast sensitivity) test in amblyopic and nonamblyopic eyes of children with unilateral amblyopia.

Methods

Children aged 3-12 years with unilateral amblyopia due to strabismus and/or anisometropia were recruited as part of a randomized trial.

n = 76 test-retest pairs
Results

test scores had to differ by this much to reflect a true change, not noise

MD 0.01 (95% CI -0.02 to 0.03)
null = 0-0.020.03
CI crosses the null - not significant
More results

In children aged 3-6 years, 81% (117/145) passed the pre-test: 17 of 34 (50%) 3-year-olds, 39 of 46 (85%) 4-year-olds, 33 of 37 (89%) 5-year-olds, and 28 of 28 (100%) 6-year-olds.

Fifty-four of 117 (46%) who passed the pre-test had matching test pairs for analysis.

In children aged 7-12 years, all 45 passed the pre-test.

More results

Twenty-two of 45 (49%) who passed the pre-test had matching test pairs for analysis.

“
Conclusion · 1 of 2

Children aged 6-12 years were more likely to be testable. Regardless of age, half of all test-retest pairs were completed incorrectly, possibly due to examiner or participant-related factors.

Conclusion · 2 of 2

A greater than 4-line (0.20 logCS) change on the SpotChecks contrast sensitivity test is required to detect a change in contrast sensitivity function beyond measurement error in children 3-12 years of age with unilateral amblyopia.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving