Translational vision science & technology · 2d
AI / informaticsTranslational vision science & technology · 2026

Deep Learning-Based Automated Segmentation and Multi-Parametric Quantitative Assessment of the Lacrimal Drainage System on CT-DCG.

Peifang Xu, Yishu Zhang, Pengjie Chen … Han Wu
Read paper
OphthalmologyAI / informatics

AI-based CT scans matched expert assessment of tear duct sac size closely.

Deep Learning-Based Automated Segmentation and Multi-Parametric Quantitative Assessment of the Lacrimal Drainage System on CT-DCG.

Peifang Xu … Han Wu
Translational vision science & technology · 2026
Background

Primary acquired nasolacrimal duct obstruction (primary acquired nasolacrimal duct obstruction) is a common cause of epiphora.

Purpose

Primary acquired nasolacrimal duct obstruction (primary acquired nasolacrimal duct obstruction) is a common cause of epiphora.

Methods

The system performed automated quantification of the long axis, short axis, and cross-sectional area for each slice from the superior to the inferior opening of the bony nasolacrimal duct, as well as for the lacrimal sac.

n = 151 patients
Results

AI matched the eye specialist's sac-size ratings most of the time

84.7%
Agreement rate
0.76%
Cohen's kappa
More results

The deep learning model achieved robust performance in segmenting the lacrimal drainage system, with an average Dice coefficient of 0.79 for the bony nasolacrimal duct.

It accurately identified and localized the narrowest cross-sectional plane and the obstruction site within the bony nasolacrimal duct.

“
Conclusion · 1 of 2

The proposed deep learning framework demonstrates the technical feasibility of automated segmentation and morphological quantification of the lacrimal sac and bony nasolacrimal duct on CT dacryocystography.

Conclusion · 2 of 2

Although further prospective validation is required, the objective anatomic metrics provided by this system hold promising potential to assist in preoperative assessment and surgical planning for primary acquired nasolacrimal duct obstruction treatment.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving