Post

New research · Ophthalmology
Medicina (Kaunas, Lithuania) · 2d
Cohort studyMedicina (Kaunas, Lithuania) · 2026

Realistic Visual Acuity and Patient Satisfaction After Simultaneous Bilateral Tecnis Eyhance DIB00 Monofocal Plus Lens Implantation During a 12-Month Follow-Up Period in a Single-Center Study.

Agnieszka Nowosielska, Grzegorz Rotuski
Read paper
OphthalmologyCohort study

Bilateral Eyhance lens implants gave 8.54/10 average patient satisfaction after 12 months

Realistic Visual Acuity and Patient Satisfaction After Simultaneous Bilateral Tecnis Eyhance DIB00 Monofocal Plus Lens Implantation During a 12-Month Follow-Up Period in a Single-Center Study.

Agnieszka Nowosielska, Grzegorz Rotuski
Medicina (Kaunas, Lithuania) · 2026
Background

The purpose of this study is to present the clinical results over a 12-month follow-up period in patients after simultaneous bilateral crystalline lens removal with implantation of a Tecnis Eyhance DIB00 monofocal plus lens.

Methods

This is a single-center, 12-month, retrospective study involving 214 eyes of 107 patients operated on between 2021 and 2023.

n = 214 eyes
Results
8.54
patients rated their satisfaction very high, close to a perfect score
n = 214 eyes
More results

Uncorrected and best-corrected visual acuity were, respectively, for a 30 cm distance UCVA 0.76/BCVA 0.18 LogMAR; for a 70 cm distance UCVA 0.03/BCVA -0.036 LogMAR; and for distance vision UCVA 0.05/BCVA 0.02.

None of the patients reported adverse phenomena such as halo, glare, contrast decrease, or other phenomena after surgery.

“
Conclusion · 1 of 2

The Tecnis Eyhance DIB00 lens implanted during bilateral cataract surgery produced good results in terms of uncorrected visual acuity under various lighting conditions, which in our population was better than predicted by the lens manufacturer.

Conclusion · 2 of 2

Through the 12-month observation period, postoperative refractive values remained stable, with no deterioration of vision.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving