Post

New research · Ophthalmology
Journal of clinical medicine · 2d
ReviewJournal of clinical medicine · 2026

Comparison of VISUMAX 800 and VISUMAX 500 Femtosecond Laser Systems for Myopia: A Systematic Review and Meta-Analysis.

Qi Wan, Ran Wei, Li Chen, Ke Ma
Read paper
OphthalmologyReview

VISUMAX 800 associated with better astigmatism axis alignment than VISUMAX 500 laser.

Comparison of VISUMAX 800 and VISUMAX 500 Femtosecond Laser Systems for Myopia: A Systematic Review and Meta-Analysis.

Qi Wan … Ke Ma
Journal of clinical medicine · 2026
Purpose

The VISUMAX 800 (Carl Zeiss Meditec) is the second-generation femtosecond laser for small incision lenticule extraction (small incision lenticule extraction), featuring faster pulse rates, automated cyclotorsion compensation (OcuLign), and automated centration (CentraLign) versus the VISUMAX 500.

Methods

Following PRISMA 2020 guidelines, we searched PubMed, EMBASE, and Web of Science through March 2026 for studies comparing the two platforms in myopia or myopic astigmatism with extractable data.

n = 1672 eyes
Results

eyes were more likely to have correctly aligned astigmatism angle with VISUMAX 800

RR 1.16 (95% CI 1.07 to 1.25)
null = 11.071.25
CI excludes the null - significant
More results

For SE ± 0.50 D, the pooled risk ratio (RR) was 1.065 (95% CI: 0.997-1.137, p = 0.061) with substantial heterogeneity (I 2 = 64.7%, p = 0.004).

For CYL ± 0.50 D (eight studies, 1585 eyes), the pooled RR was 1.022 (95% CI: 0.978-1.068, p = 0.333, I 2 = 51.7%).

More results

No statistically significant differences were observed for UDVA ≥ 20/20, safety, SEQ R 2 , cylinder R 2 , TIA, SIA, total HOAs, spherical aberration, or coma RMS.

Publication bias tests showed no significant asymmetry for the primary outcomes, though these tests have limited power with fewer than 10 studies.

“
Conclusion · 1 of 2

Both platforms yield comparable predictability, safety, and visual outcomes. VISUMAX 800 offers superior astigmatism axis alignment, likely due to automated compensation and centration.

Conclusion · 2 of 2

The borderline SE predictability warrants further randomized investigation.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving