Post

New research · Ophthalmology
Life (Basel, Switzerland) · 2d
Randomized trialLife (Basel, Switzerland) · 2026

Short-Term Impact of Scleral Lens Wear on Intraocular Pressure and Retinal Nerve Fiber Layer Thickness.

Pabita Dhungel, Muteb K Alanazi, Patrick Caroline … Maria Liu
Read paper
OphthalmologyRandomized trial

Scleral contact lenses temporarily raise eye pressure within hours of wear

Short-Term Impact of Scleral Lens Wear on Intraocular Pressure and Retinal Nerve Fiber Layer Thickness.

Pabita Dhungel … Maria Liu
Life (Basel, Switzerland) · 2026
Purpose

To investigate the short-term impact of scleral lens wear on intraocular pressure (IOP) and retinal nerve fiber layer (retinal nerve fiber layer) thickness.

Methods

This prospective, randomized, contralateral-eye crossover study included 31 healthy participants (mean age: 26 ± 3 years).

n = 31 healthy participants
Results

eye pressure measured while wearing the lens, higher than before

Pre-application
11mmHg
Post-application
16mmHg
More results

No significant IOP changes were observed in soft contact lens-wearing eyes ( p > 0.05).

Scleral lens wear was also associated with small but statistically significant peripapillary retinal nerve fiber layer thinning (pre-application: 110 ± 11 µm vs. post-application: 107 ± 11 µm, p < 0.001), which returned to baseline after lens removal.

More results

No significant retinal nerve fiber layer changes were observed with soft contact lens wear ( p > 0.05).

Bland-Altman analysis revealed poor agreement between Diaton and non-contact tonometer measurements, consistent with the published literature on transpalpebral tonometry.

“
Conclusion · 1 of 2

Short-term scleral lens wear was associated with transient IOP elevation and peripapillary retinal nerve fiber layer thinning, both reversible upon lens removal, in healthy young adults.

Conclusion · 2 of 2

These findings highlight the need for further longitudinal investigation in at-risk populations such as those with ocular hypertension, keratoconus, or early glaucoma before clinical monitoring recommendations can be established.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Cross-sectional
44.1%
had too much homocysteine in the blood, a far larger share than in dry AMD or healthy eyes
Cohort Study
92.3%
most laser-treated eyes had a favorable eye-structure outcome
Cohort Study
56%
lost three or more lines on the eye-chart vision test
Cohort Study
50%
older patients were more likely to lose three or more lines of vision
Study
81%
trials where mask air leaks were detected blowing toward the eyes
Cohort Study
13.5%
Central retinal artery peak blood-flow speed was 13.5% lower in diabetic patients.
Study
379 +/- 156 microm
lower thickness in the central retina, checked with an eye scan
Case Report
9 of 10 eyes
eyes had better measured vision after treatment