Post

New research · Ophthalmology
Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 3d
StudyOphthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026

Scleral Lens Fenestrations and Fluid Reservoir Debris.

Damien Fisher, Luisa Holguin Colorado, David Alonso-Caneiro, Stephen J Vincent
Read paper
OphthalmologyStudy

Fenestrated scleral lenses accumulate less fluid reservoir debris than non-fenestrated lenses

Scleral Lens Fenestrations and Fluid Reservoir Debris.

Damien Fisher … Stephen J Vincent
Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
Background

The accumulation of debris within the fluid reservoir during scleral lens wear can adversely affect vision, resulting in the need for lens removal.

Purpose

This study aimed to quantify the effect of incorporating limbal scleral lens fenestrations upon fluid reservoir debris.

Methods

Twenty healthy adults (mean age 32 ± 11 years, 10 females/10 males) with normal corneas wore non-fenestrated and fenestrated (3 × 1 mm diameter limbal fenestrations separated by 120°) OneFitMed+ scleral lenses (No.7 Contact Lenses) in both eyes (on separate days) for 3 h.

Results

non-fenestrated lenses build up far more debris in the fluid layer

66arbitr
Non-fenestrated
14arbitr
Fenestrated
More results

Fluid reservoir debris increased over time (p < 0.001), more so for non-fenestrated lenses.

More results

After 3 h, the increase in fluid reservoir debris was greater for the non-fenestrated lens design (total metric increase: non-fenestrated 66 ± 21 vs fenestrated 14 ± 7 arbitrary units [p = 0.03], average metric increase: non-fenestrated 9 ± 2 vs fenestrated 5 ± 1 arbitrary units [p = 0.07]).

“
Conclusion · 1 of 3

After 3 h, non-fenestrated lenses displayed a 2 (average metric) to 4.8 times (total metric) greater increase in central fluid reservoir debris than fenestrated lenses.

Conclusion · 2 of 3

This suggests a potential role for fenestrated lens designs in managing fluid reservoir debris; however, longer-term studies of participants with ocular disease are required.

Conclusion · 3 of 3

CLINICAL TRIAL: This study was registered on the Australian New Zealand Clinical Trials Registry (Registration number 12622001164785p), date of registration 24/8/2022.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving