Post

New research · Ophthalmology
Ocular immunology and inflammation · 4d
Cohort studyOcular immunology and inflammation · 2026

Efficacy of PAUL Glaucoma Implant® for Refractory Uveitic Glaucoma.

Samy Si Larbi, Bahram Bodaghi, Valérie Touitou … Agathe Vest
Read paper
OphthalmologyCohort study

Paul Glaucoma Implant markedly lowered eye pressure in refractory uveitic glaucoma at 2 years.

Efficacy of PAUL Glaucoma Implant® for Refractory Uveitic Glaucoma.

Samy Si Larbi … Agathe Vest
Ocular immunology and inflammation · 2026
Purpose

Evaluate the mid-term efficacy and safety of Paul Glaucoma Implant (Paul Glaucoma Implant) in patients with refractory uveitic glaucoma (refractory uveitic glaucoma).

Methods

Aged 18 years or older with refractory uveitic glaucoma and uncontrolled intraocular pressure (IOP) who underwent Paul Glaucoma Implant implantation between November 2021 and January 2025 at a tertiary uveitis center were included.

n = 25 eyes
Results

eye pressure was much lower after surgery, easing strain on the eye

72%
Before
87.5%
After
More results

Mean preoperative IOP was 25.5 ± 7.7 mmHg with 3.5 ± 1.1 medications.

Complete success decreased from 28% at 6 months to 12.5% at 24 months, while qualified success increased from 72% to 87.5%.

Visual field mean deviation remained stable (mean change -0.79 dB; p = 0.21).

More results

Surgical reintervention was required in 2 eyes (8%).

“
Conclusion · 1 of 2

Paul Glaucoma Implant provided sustained IOP reduction with a favorable safety profile in a refractory uveitic glaucoma population.

Conclusion · 2 of 2

These findings support the Paul Glaucoma Implant as a valuable surgical option in UG, although larger multicenter comparative studies are needed.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Cross-sectional
44.1%
had too much homocysteine in the blood, a far larger share than in dry AMD or healthy eyes
Cohort Study
92.3%
most laser-treated eyes had a favorable eye-structure outcome
Cohort Study
56%
lost three or more lines on the eye-chart vision test
Cohort Study
50%
older patients were more likely to lose three or more lines of vision
Study
81%
trials where mask air leaks were detected blowing toward the eyes
Cohort Study
13.5%
Central retinal artery peak blood-flow speed was 13.5% lower in diabetic patients.
Study
379 +/- 156 microm
lower thickness in the central retina, checked with an eye scan
Case Report
9 of 10 eyes