Post

New research · Ophthalmology
Ophthalmology · 6d
ReviewOphthalmology · 2025

Instrument-Based Screening for the Detection of Amblyopia and Amblyopia Risk Factors: A Report by the American Academy of Ophthalmology.

Julius T Oatts, Megan E Collins, Kara M Cavuoto … Melinda Y Chang
Read paper
OphthalmologyReview

Instrument screening sensitivity for amblyopia risk factors varied widely across studies.

Instrument-Based Screening for the Detection of Amblyopia and Amblyopia Risk Factors: A Report by the American Academy of Ophthalmology.

Julius T Oatts … Melinda Y Chang
Ophthalmology · 2025
Purpose

To review the published literature on the diagnostic accuracy of instrument-based screening devices used to detect amblyopia and amblyopia risk factors (amblyopia risk factors).

Methods

The panel methodologist assigned a level of evidence rating to each of the included studies.

n = 072 children
Results

Devices identified 32.3% to 100% of children with amblyopia risk factors.

32.3%
Sensitivity
38.7%
Specificity
More results

All 33 articles (which reported results from 28 072 children) were rated level III.

Results from 28 072 children were reported, and most studies focused on children aged 6 years and younger.

More results

Examination failure thresholds varied, but most studies after 2013 followed the 2013 American Association for Pediatric Ophthalmology and Strabismus (Association for Pediatric Ophthalmology and Strabismus) guidelines.

“
Conclusion · 1 of 2

The best available evidence supports the use of instrument-based screening devices to detect amblyopia and amblyopia risk factors, although there were high levels of variability in the study design, setting, and target age for screening.

Conclusion · 2 of 2

Additionally, diagnostic accuracy varied on the basis of the screening device used.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
AI / Informatics
0·962 for OCT
MerMED-FM was very accurate at diagnosing diseases using eye scans
AI / Informatics
0.98
Artificial intelligence's eyelid-height measurements matched doctors' manual measurements almost perfectly
AI / Informatics
92.1%
combining eye scans and photos correctly told benign from cancerous lesions apart nearly every time
Cohort Study
28.6%
recurred locally in more than 1 in 4 patients over years of follow-up
Cohort Study
-0.395
excision group's post-op eyelid fullness score was lower - greater improvement
Cohort Study
86.7%
of infants probed after 12 months still had unresolved tear duct blockage
Observational
16%
eyelid tissue in rosacea patients showed less of this key repair-signaling protein inside cell nuclei
Cohort Study
25%
about 1 in 4 treated cases had symptoms return after improving