Post

New research · Surgery
JAMA surgery · 1d
Cohort studyJAMA surgery · 2026

Indocyanine Green Fluorescent Cholangiography During Laparoscopic Cholecystectomy and Bile Duct Injury.

Nicholas C Neel, Lola Van Doosselaere, Nikita S Thareja … Winta T Mehtsun
Read paper
SurgeryCohort study

Indocyanine green use is associated with lower common bile duct injury rates.

Indocyanine Green Fluorescent Cholangiography During Laparoscopic Cholecystectomy and Bile Duct Injury.

Nicholas C Neel et al. · JAMA surgery · 2026
Background

IMPORTANCE: Common bile duct (CBD) injury is a rare but devastating complication of laparoscopic cholecystectomy.

Purpose

To evaluate the association between intraoperative ICG use and CBD injury after laparoscopic cholecystectomy.

Methods

DESIGN, SETTING, AND PARTICIPANTS: This cohort study included data from multiple hospitals in the Epic Cosmos dataset for adult patients (18 years and older) undergoing laparoscopic cholecystectomy between 2016 and 2024.

n = 1143 patients
Results

using ICG leads to a 38% lower chance of common bile duct injury

RR 0.62 (95% CI 0.49 to 0.79)
null = 10.490.79
CI excludes the null - significant
More results

Among them, 118 626 (72.0) were female and 46 069 (28.0) were male; the mean (SD) age was 51 (17) years.

ICG use increased from 1143 patients (1.6%) in 2016 to 47 816 (26%) in 2024.

“
Conclusion · 1 of 2

In this large national cohort, intraoperative ICG use was associated with lower rates of CBD injury, fewer postoperative biliary procedures and nonbiliary complications, and reduced conversion to open surgery.

Conclusion · 2 of 2

These findings support the use of ICG to enhance biliary safety in laparoscopic cholecystectomy and demonstrate its utility in reducing CBD injury.

Read paper
0 comments

No comments yet. Be the first.

Related papers

LatestFoundational
Review
107 publications
volume of research papers identified on robot-assisted kidney donation surgery
Cohort Study
86.2%
patients had no urine leakage after receiving the implanted device
Cohort Study
0.58
how well patients' own frailty ratings matched trained assessors' ratings
Cohort Study
59.0%
Over two years, 59.0% of patients achieved lower eye pressure or fewer medications.
Cohort Study
4.8% vs. 7.1%
serious problems after live-streamed surgery were similar to non-streamed surgery
Study
9.91 dB
average error in predicting hearing after ear surgery, with lower values being better
Cohort Study
3:54 vs. 4:41 h
recipients had shorter surgery time with the simultaneous robotic approach
Observational
78%
the middle turbinate stayed in a stable position for most patients with the graft